The process connection to the actual machines/sensors.
MQTT (Message Queuing Telemetry Transport) is a messaging protocol which works on top of the TCP/IP protocol and is meant for communication in networks with limited bandwidth.
Release Notes, Update information, Certifications and Frequently Asked Questions.
Your first step into modern and powerful process visualization.
Topics, you need to know, before using WinCC OA.
Go beyond the norm in cybersecurity.
Powerful tools for easy or complex engineering tasks.
Classify, structure and archive your data.
Endless possibilities in data processing for your projects.
User interfaces, Trends and Reports for every purpose and device.
The WinCC OA S7Plus driver uses the Siemens communication library IOMS and is meant for the communication with Siemens S7 PLCs.
The WinCC OA S7 driver is a native driver for connection to the periphery with Siemens S7 PLCs.
OPC Unified Architecture (in short OPC UA) is the most recent OPC specification from the OPC Foundation and differs significantly from its predecessors (DA, A&E, HDA). OPC UA forms a new standard, which is completely based on a service-oriented architecture.
This chapter explains the most important terms and presents the steps involved in starting a functioning OPC communication. The individual points will be dealt with in more detail in the subsequent chapters.
The WinCC OA OPC (OLE for Process Control) HDA client allows to query, display and save historical data from OPC HDA servers.
OPC Alarms & Events (brief OPC A&E) is in addition to the Data Access another standard in order to implement a central alert management manufacturer spanning. OPC A&E is used to guarantee the coupling with other control systems as well as to display alerts and events in a hierarchical system
IEC drivers are standardized remote control drivers that can contain proprietary telegrams.
IEC 61850 defines an architecture for meeting the needs of electrical substation automation.
Modbus/TCP is an adaptation of the serial Modbus protocol for TCP/IP communication. The Modbus/TCP driver can be used for Modbus/TCP or UNICOS at the same time.
SNMP (Simple Network Management Protocol) is a protocol for monitoring network devices (servers, workstations, routers, switches and hubs etc.) and their functions. It allows you to administer your network.
BACnet (Building Automation and Control Networks) is a normed protocol for building automation and was designed by ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) in order to provide a consistent and intraoperative standard for data communication in and with systems of building automation.
The WinCC OA DNP3(Distributed Network Protocol 3) driver uses an open, robust and modern protocol, which has similar characteristics and strong points like the IEC Driver. The transmission of any number of telegrams with different data types occurs between the WinCC OA system (master) and the outstation (slave).
Ethernet/IP is used to communicate with multiple generations and families of Rockwell Automation / Allen Bradley PLCs. It is an application layer protocol, layered on top of standard TCP/IP networking.
Settings for the MQTT driver.
These instructions will guide you through the required steps of setting up a certificate chain for the MQTT driver. In this example WinCC OA and the Mosquitto are used.
As an application profile of PROFINET, PROFIsafe is responsible for the communication between safety devices (F-Device) and safety controllers (F-Host).
The WinCC OA S-Bus driver is used for the connection from SAIA PCD control devices to WinCC OA projects.
The WinCC OA SSI driver is used for interfacing SAT remote systems.
SINAUT (SIemens Network AUTomation) is a communication protocol for automatic monitoring and controlling of remote process stations on basis of SIMATIC S7 developed by Siemens.
The WinCC OA driver RK512 is used for interfacing a programmable logic controller using the 3964R/RK512 protocol.
The WinCC OA simulator assumes the tasks of a driver without being connected to actual peripherals. This means it simulates the periphery and is able to generate values "spontaneously". It does this by passing data to the Event Manager that this manager would receive from system components during normal operation of a system. The control system functions can be tested after configuration.
NTCIP (National Transportation Communications for ITS Protocol) is a family of open standards for the configuration, control and monitoring of traffic control equipment (e.g. traffic lights, dynamic message signs, vehicle counting).
The WinCC OA TLS gateway (Technical Delivery Terms for Route Stations) is a standard for using and establishing traffic control systems on roads.
Your portal to the cloud or supervising systems.
Data exchange, APIs and web technologies
All about authorization, authentication and login-customization.
How to get your system uptime to the maximum.
Create state of the art project reports without limits.
Useful tools and enhancements for special demands.
Detailed and extensive content for special project adaptation.
Explore the capabilities of WinCC OA with our carefully selected collection of video tutorials and guides.
Basic information about terms and functions within the documentation.
A brief clarification of liability exclusions or legal notices.